Description
Fluke 116/323 HVAC Combo Kit – Includes Multimeter and Clamp Meter
For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
Specifications
Fluke 116
- DC millivolts
- Range/resolution 600.0 mV / 0.1 mV
- Accuracy ±0.5% 2
- DC volts
- Range/resolution
- 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
- Accuracy ±0.5% 2
- Auto volts
- Range/resolution 600.0 V / 0.1 V
- Accuracy
- 2.0% 3 (DC, 45 Hz to 500 Hz)
4.0% 3 (500 Hz to 1 kHz)
- AC millivolts¹ True RMS
- Range/resolution 600.0 mV / 0.1 mV
- Accuracy
- 1.0% 3 (DC, 45 Hz to 500 Hz)
2.0% 3 (500 Hz to 1 kHz)
- AC volts¹ True RMS
- Range/resolution
- 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
- Accuracy
- 1.0% 3 (DC, 45 Hz to 500 Hz)
2.0% 3 (500 Hz to 1 kHz)
- Continuity
- Range/resolution 600 Ω / 1 Ω
- Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
- Ohms
- Range/resolution
- 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
- Accuracy 0.9% 1
- Range/resolution 40.00 MΩ / 0.01 MΩ
- Accuracy 5% 2
- Diode test
- Range/resolution 2.00 V / 0.001 V
- Accuracy 0.9% 2
- Capacitance
- Range/resolution
- 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
- Accuracy 1.9% 2
- Range/resolution > 1000 μF
- Lo-Z capacitance
- Range 1 nF to 500 μF
- Accuracy 10% 2 typical
- Temperature² (Type-K thermocouple)
- Range/resolution -40°C to 400°C / 0.1°C
- Accuracy 1% 10²
- Range/resolution -40°F to 752°F / 0.2°F
- Accuracy 1% 18²
- AC μA true-RMS (45 Hz to 500 Hz)
- Range/resolution 600.0 μA / 0.1 μA
- Accuracy 1.5% 3
- DC μamps
- Range/resolution 600.0 μA / 0.1 μA
- Hz (V or A input)²
- Range/resolution
- 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
- Accuracy 0.1% 2
- All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
- Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
- Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
- Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
|
- Maximum voltage between any terminal and earth ground 600 V
- Environmental
- Operating Temperature -10°C to 50°C
- Storage Temperature -40°C to 60°C
- Safety
- Surge protection
- 6 kV peak per IEC 61010–1 600 V CAT III,
- Pollution Degree 2
- Display
- Digital: 6,000 counts, updates 4 per second
- Bar graph
- 33 segments, updates 32 per second
- Features
- VoltAlert™ technology for non-contact voltage detection
- AutoVolt automatic AC/DC voltage selection
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- True RMS for accurate measurements on non-linear loads
- Measures 10 A (20 A overload for 30-seconds)
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™) for hands free operation
- CAT III 600 V safety rated
- Mechanical & General
- Size 167 x 84 x 46 mm
- Weight 550 g
- Warranty 3 years
- Battery Life 9 volt Alkaline:~400 hours typical, without backlight
- Included accessories:
- 4 mm silicone test lead set
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
- User manual
- Optional Accessories
- Cases, bags and holsters
- Meter hanger kits
- Probes
- HV
- Current clamp
- Fibre Optic
- Pressure
- Temperature
- Test Leads
- Clips
- Probe lights
|
Fluke 62 MAX Infrared Thermometer
- Temperature
- Range -30 °C to 650 °C (-22 °F to 1202 °F)
- Accuracy
- ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
- Response Time (95%)
- Fluke 62 MAX <300 ms (95% of reading)
- Spectral Response 8 to 14 microns
- Emissivity 0.10 to 1.00
- Resolution
- Optical 12:1 (calculated at 90% energy)
- Display 0.1 °C (0.2 °F)
- Repeatability of Readings
- ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
- AC current
- Range 400.0 A
- Accuracy
- 2 % ± 5 digits (45 Hz to 65 Hz)
2.5 % ± 5 digits (65 Hz to 400 Hz)
|
- Mechanical & General
- Size 175 x 85 x 75 mm
- Weight 255 g
- Warranty 2 year
- Battery life Alkaline AA ~ 8 hours with laser and backlight on
- Environmental
- Operating Temperature 0 °C to 50 °C
- Storage Temperature -20 °C to 60 °C
- Operating Humidity 10 % to 90 % RH non-condensing at 30 °C
- Operating Altitude 2000 meters above mean sea level
- Storage Altitude 12,000 meters above mean sea level
- IP Rating IP 54 per IEC 60529
- Drop Test 3 meters
- Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
- EMC EN 61326-1:2006 EN 61326-2:2006
- Safety
- Standards and Agency Approval
- Compliance EN/IEC 61010-1: 2001
- Laser Safety FDA and EN 60825-1 Class II
- Features
- Key Benefits
- Dust and water-resistant: IP54 rated for dust and water resistance.
- Rugged: 3-meter (9.8-foot) drop tested.
- Completely redesigned for a more natural hand fit.
- Small,lightweight and clips to your tool belt or belt loop and easily fits into your tool box.
- Additional Features
- Distance to spot: Precise laser technology makes for more accurate and repeatable measurements.
- Dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots.
- Large screen with backlight makes data easier to read, even in dark areas.
- Displays the minimum, maximum or average temperature, or the difference between two measurements.
- Hi and Lo alarms for rapid display of measurements outside the limits.
- Powered by a single, standard AA battery.
|
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.