Fluke 117

Fluke 117

Description

Electrician’s Multimeter with Non-Contact Voltage

With its integrated non-contact voltage detection and the AutoV/LoZ function preventing false readings caused by ghost voltage, the Fluke 117 Electrician’s Multimeter is the ideal multimeter for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings, measuring frequency and capacitance. With its easy-to-use design, the Fluke 117 will save you time, allowing you to move from job to job with ease.

Engineered and Tested with Your Safety on the Job in Mind

We test our 117 Multimeters for safe use in CAT III 600 V environments. This is the ideal meter for your electrical work because:

  • The large white LED backlight helps you work in poorly lit areas
  • VoltAlertTM technology gives you fact, go/no go non-contact voltage detection
  • AutoVolt and Low Input Impedance modes provide faster, more accurate readings

Specifications

  • DC millivolts
    • Range/resolution 600.0 mV / 0.1 mV
    • Accuracy ±0.5% 2
  • DC volts
    • Range/resolution
      • 6.000 V / 0.001 V

        60.00 V / 0.01 V

        600.00 V / 0.1 V

    • Accuracy ±0.5% 2
  • Auto volts
    • Range/resolution 600.0 V / 0.1 V
    • Accuracy
      • 2.0% 3 (DC, 45 Hz to 500 Hz)

        4.0% 3 (500 Hz to 1 kHz)

  • AC millivolts¹ True RMS
    • Range/resolution 600.0 mV / 0.1 mV
    • Accuracy
      • 1.0% 3 (DC, 45 Hz to 500 Hz)

        2.0% 3 (500 Hz to 1 kHz)

  • AC volts¹ True RMS
    • Range/resolution
      • 6.000 V / 0.001 V

        60.00 V / 0.01 V

        600.0 V / 0.1 V

    • Accuracy
      • 1.0% 3 (DC, 45 Hz to 500 Hz)

        2.0% 3 (500 Hz to 1 kHz)

  • Continuity
    • Range/resolution 600 Ω / 1 Ω
    • Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of

      500 μs or longer.

  • Ohms
    • Range/resolution
      • 600.0 Ω / 0.1 Ω

        6.000 kΩ / 0.001 kΩ

        60.00 kΩ / 0.01 kΩ

        600.0 kΩ / 0.1 kΩ

        6.000 MΩ / 0.001 MΩ

      • Accuracy 0.9% 1
    • Range/resolution 40.00 MΩ / 0.01 MΩ
      • Accuracy 5% 2
  • Diode test
    • Range/resolution 2.00 V / 0.001 V
    • Accuracy 0.9% 2
  • Capacitance
    • Range/resolution
      • 1000 nF / 1 nF

        10.00 μF / 0.01 μF

        100.0 μF / 0.1 μF

        9999 μF / 1 μF

        100 μF to 1000 μF

      • Accuracy 1.9% 2
    • Range/resolution > 1000 μF
      • Accuracy 5% 20%
  • Lo-Z capacitance
    • Range 1 nF to 500 μF
    • Accuracy 10% 2 typical
  • AC amps True RMS (45 Hz to 500 Hz)
    • Range/resolution
      • 6.000 A / 0.001 A

        10.00 A / 0.01 A

    • Accuracy
      • 1.5% 3

        20 A continuous overload for 30 seconds max

  • DC amps
    • Range/resolution
      • 6.000 A / 0.001 A

        10.00 A / 0.01 A

    • Accuracy
      • 1.0% 3

        20 A continuous overload for 30 seconds max

  • Hz (V or A input)²
    • Range/resolution
      • 99.99 Hz / 0.01 Hz

        999.99 Hz / 0.1 Hz

        9.999 Hz / 0.001 Hz

        50.00 Hz / 0.01 Hz

    • Accuracy 0.1% 2
  1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
  2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
  3. Accuracies are specified as ±([% of reading] [counts])
  •  Maximum voltage between any terminal and earth ground 600 V
  • Environmental
    • Operating Temperature  -10°C to 50°C
    • Storage Temperature  -40°C to 60°C
  • Safety
    • Surge protection
      • 6 kV peak per IEC 61010–1 600 V CAT III,
      • Pollution Degree 2
    • Fuse for A input
      • 11 A, 1000 V FAST Fuse (Fluke PN 803293)
  • Display
    • Digital: 6,000 counts, updates 4 per second
  • Bar graph
    • 33 segments, updates 32 per second
  • Features
    • VoltAlert™ technology for non-contact voltage detection
    • AutoVolt automatic AC/DC voltage selection
    • Low input impedance: helps prevent false readings due to ghost voltage
    • Large white LED backlight to work in poorly lit areas
    • True RMS for accurate measurements on non-linear loads
    • Measures 10 A (20 A overload for 30-seconds)
    • Resistance, continuity, frequency and capacitance
    • Min/Max/Average with elapsed time to record signal fluctuations
    • Compact ergonomic design for one-handed operation
    • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
    • CAT III 600 V safety rated
  • Mechanical & General
    • Size  167 x 84 x 46 mm
    • Weight  550 g
    • Warranty 3 years
    • Battery Life  9 volt Alkaline:~400 hours typical, without backlight
  • Included accessories:
    • 4 mm silicone test lead set
    • Holster
    • User manual
  • Optional Accessories
    • Cases, bags and holsters
    • Meter hanger kits
    • Probes
      • HV
      • Current clamp
      • Fibre Optic
      • Pressure
      • Temperature
    • Test Leads
    • Clips
    • Probe lights

 

Additional information

Weight 0.42 kg
Dimensions 19 × 8.5 × 4.5 cm

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.