Fluke 116/323 HVAC Combo Kit

Description

For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

Specifications

Fluke 116

  • DC millivolts
    • Range/resolution 600.0 mV / 0.1 mV
    • Accuracy ±0.5% 2
  • DC volts
    • Range/resolution
      • 6.000 V / 0.001 V
        60.00 V / 0.01 V
        600.00 V / 0.1 V
    • Accuracy ±0.5% 2
  • Auto volts
    • Range/resolution 600.0 V / 0.1 V
    • Accuracy
      • 2.0% 3 (DC, 45 Hz to 500 Hz)
        4.0% 3 (500 Hz to 1 kHz)
  • AC millivolts¹ True RMS
    • Range/resolution 600.0 mV / 0.1 mV
    • Accuracy
      • 1.0% 3 (DC, 45 Hz to 500 Hz)
        2.0% 3 (500 Hz to 1 kHz)
  • AC volts¹ True RMS
    • Range/resolution
      • 6.000 V / 0.001 V
        60.00 V / 0.01 V
        600.0 V / 0.1 V
    • Accuracy
      • 1.0% 3 (DC, 45 Hz to 500 Hz)
        2.0% 3 (500 Hz to 1 kHz)
  • Continuity
    • Range/resolution 600 Ω / 1 Ω
    • Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
      500 μs or longer.
  • Ohms
    • Range/resolution
      • 600.0 Ω / 0.1 Ω
        6.000 kΩ / 0.001 kΩ
        60.00 kΩ / 0.01 kΩ
        600.0 kΩ / 0.1 kΩ
        6.000 MΩ / 0.001 MΩ
    • Accuracy 0.9% 1
    • Range/resolution 40.00 MΩ / 0.01 MΩ
    • Accuracy 5% 2
  • Diode test
    • Range/resolution 2.00 V / 0.001 V
    • Accuracy 0.9% 2
  • Capacitance
    • Range/resolution
      • 1000 nF / 1 nF
        10.00 μF / 0.01 μF
        100.0 μF / 0.1 μF
        9999 μF / 1 μF
        100 μF to 1000 μF
      • Accuracy 1.9% 2
    • Range/resolution > 1000 μF
      • Accuracy 5% 20%
  • Lo-Z capacitance
    • Range 1 nF to 500 μF
    • Accuracy 10% 2 typical
  • Temperature² (Type-K thermocouple)
    • Range/resolution -40°C to 400°C / 0.1°C
    • Accuracy 1% 10²
    • Range/resolution -40°F to 752°F / 0.2°F
    • Accuracy 1% 18²
  • AC μA true-RMS (45 Hz to 500 Hz)
    • Range/resolution 600.0 μA / 0.1 μA
    • Accuracy 1.5% 3
  • DC μamps
    • Range/resolution 600.0 μA / 0.1 μA
  • Hz (V or A input)²
    • Range/resolution
      • 99.99 Hz / 0.01 Hz
        999.99 Hz / 0.1 Hz
        9.999 Hz / 0.001 Hz
        50.00 Hz / 0.01 Hz
    • Accuracy 0.1% 2
  1. All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
  2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
  3. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
  4. Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
  •  Maximum voltage between any terminal and earth ground 600 V
  • Environmental
    • Operating Temperature  -10°C to 50°C
    • Storage Temperature  -40°C to 60°C
  • Safety
    • Surge protection
      • 6 kV peak per IEC 61010–1 600 V CAT III,
      • Pollution Degree 2
  • Display
    • Digital: 6,000 counts, updates 4 per second
  • Bar graph
    • 33 segments, updates 32 per second
  • Features
    • VoltAlert™ technology for non-contact voltage detection
    • AutoVolt automatic AC/DC voltage selection
    • Low input impedance: helps prevent false readings due to ghost voltage
    • Large white LED backlight to work in poorly lit areas
    • True RMS for accurate measurements on non-linear loads
    • Measures 10 A (20 A overload for 30-seconds)
    • Resistance, continuity, frequency and capacitance
    • Min/Max/Average with elapsed time to record signal fluctuations
    • Compact ergonomic design for one-handed operation
    • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
    • CAT III 600 V safety rated
  • Mechanical & General
    • Size  167 x 84 x 46 mm
    • Weight  550 g
    • Warranty 3 years
    • Battery Life  9 volt Alkaline:~400 hours typical, without backlight
  • Included accessories:
    • 4 mm silicone test lead set
    • 80BK Integrated Temperature probe
    • Holster
    • Installed 9 V battery
    • User manual
  • Optional Accessories
    • Cases, bags and holsters
    • Meter hanger kits
    • Probes
      • HV
      • Current clamp
      • Fibre Optic
      • Pressure
      • Temperature
    • Test Leads
    • Clips
    • Probe lights

Fluke 323

  • DC volts
    • Range 600.0 V
    • Accuracy 1.0 % ± 5 digits
  • AC volts – True-RMS
    • Range/resolution 600.0 V
    • Accuracy 1.5 % ± 5 digits
  • Continuity
    • ≤ 70 Ω
  • Ohms
    • Range 400.0 Ω/ 4000 Ω
    • Accuracy 1.0 % ± 5 digits
  • AC current
    • Range 400.0 A
    • Accuracy
      • 2 % ± 5 digits (45 Hz to 65 Hz)
        2.5 % ± 5 digits (65 Hz to 400 Hz)
  • Mechanical & General
    • Size  207 x 75 x 34 mm
    • Weight  265 g
    • Warranty 2 year
  • Safety
    • Category rating
      • CAT III 600 V
        CAT IV 300 V
  • Features
    • 400 A ac current measurement.
    • 600 V ac and dc voltage measurement.
    • True-rms ac voltage and current for accurate measurements on non-linear signals.
    • Resistance measurement up to 40 kΩ with continuity detection.
    • Slim, ergonomic design.
    • CAT IV 300V/CAT III 600 V safety rating.

Additional information

Weight 0.42 kg
Dimensions 19 × 8.5 × 4.5 cm

Reviews