Description
One instrument for all electrical safety tests and Power Quality analysis
T60 3 Phase Power Quality Analyser has a colour display and was designed with the aim of making safety of electrical installations visible and valuable, easily and quickly.
Thanks to the new HTOS™ system the unit displays a message OK – NOT OK after completing the test.
The user interface, totally updated under HTOS™, permits to set and carry out measurements in few steps.
You can store all recorded data and create folders and sub-folders for each kind of test adding comments and notes by means of virtual keyboard.
T60 is also a three-phase power and energy consumption analyzer boasting, as unique feature, its FREE APP HTAnalysis compatible with iOS and Android.
Test results can be transferred through Wi-Fi onto smartphone or tablet enclosing a picture, a video or a voice note to each measurement. You can transfer everything onto HT Cloud and make data available in real time for your colleagues all over the world.
T60 makes the job of installer, electrician or consultant easy, rapid and cost-effective.
Features
- Touchscreen colour display
- Integrated WiFi connection and compatibility with HTANALYSIS App
- Continuity of protective circuit with 200mA
- Insulation with voltage 50, 100, 250, 500, 1000VDC
- Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA
- Time/Current tripping of type B RCDs up to 300mA
- Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A
- Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current
- Line/Loop impedance with high resolution (with optional accessory IMP57)
- Percentage voltage drop on the line
- Measurement and recording of leakage currents and environment parameters
- Three-phase Power quality and Energy consumption analysis
- 9 types of electrical systems
- 1Φ-2wires
- 1Φ-split phase
- 3Φ-3 wires, 3Φ-Aron
- 3Φ-Open Δ
- 3Φ-Open Y
- 3Φ-2 el. 1/2
- 3Φ-4 wires Y
- 3Φ-High Leg.
- 632 parameters can be recorded for over two months
- Voltage Anomalies (dips and peaks) with a resolution of 20ms @50Hz
- Measurement/recording of Active, Reactive, Apparent Power
- Measurement/recording of Active, Reactive, Apparent Energy
- Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%
- Recording autonomy higher than one month with 64 quantities and IP =15 minutes
- Voltage/current vector diagram
- Voltage/current waveforms
- Tables or histograms of Harmonics and THD%
- Summary table of main electric parameters
- Help on line on the display
- Protection category – CAT IV
Technical Overview
| ELECTRICAL SPECIFICATIONS – SAFETY SECTION (*)
Accuracy is indicated as ± (% readings no. of digits * resolution) at 23°C ± 5°C, <80%HR |
||||
| Voltage (RCD, LOOP, Phase sequence) | ||||
| Range (V) | Resolution (V) | Accuracy | ||
| 15 – 460 | 1 | ±(3.0% rdg 2dgt) | ||
| Frequency | ||||
| Range (Hz) | Resolution (Hz) | Accuracy | ||
| 47.0 – 63.6 | 0.1 | ±(0.1% rdg 1dgt) | ||
| Continuity test on protective and equalizing conductors | ||||
| Range (W) | Resolution (W) | Accuracy (*) | ||
| 0.01 – 19.99
20.0 – 99.9 |
0.01
0.1 |
±(5.0%rdg 3dgt) | ||
| (*) calibrate the cables to null their resistance | ||||
| Test current
Open-circuit voltage: Safety protection: |
> 200mA DC for R ≤ 5Ω (calibration included) ; Resolution for DC current :1mA
4V ≤ Vo ≤ 12V The display shows an error message for input voltage > approx. 10V |
|||
| Insulation resistance (DC voltage) | ||||
| Test voltage (V) | Range (MW) | Resolution (MW) | Accuracy | |
| 50 | 0.01 – 9.99
10.0 – 49.9 50.0 – 99.9 |
0.01
0.1 0.1 |
±(2.0%rdg 2dgt)
. ±(5.0%rdg 2dgt |
|
| 100 | 0.01 – 9.99
10.0 – 99.9 100.0 – 199.9 |
0.01
0.1 0.1 |
±(2.0%rdg 2dgt)
. ±(5.0%rdg 2dgt) |
|
| 250 | 0.01 – 9.99
10.0 – 99.9 100 – 499 |
0.01
0.1 1 |
±(2.0%rdg 2dgt)
. ±(5.0%rdg 2dgt |
|
| 500 | 0.01 – 9.99
10.0 – 199.9 200 – 499 500 – 999 |
0.01
0.1 1 1 |
±(2.0%rdg 2dgt)
. . ±(5.0%rdg 2dgt) |
|
| 1000 | 0.01 – 9.99
10.0 – 199.9 200 – 999 1000 – 1999 |
0.01
0.1 1 1 |
±(2.0%rdg 2dgt)
. . ±(5.0%rdg 2dgt) |
|
| Open-circuit voltage:
Short circuit current: Nominal test current: Safety protection: |
nominal test voltage –0% 10%
<6.0mA at 500V test voltage >1mA if load= 1kW * Vnom (Vnom = 50V, 100V, 250V, 500V, 1000V) the display shows an error message for input voltage > approx.10V |
|||
| Z Line (Line-Line, Line-Neutral, Line-PE) | ||||
| Range [W] | Resolution [W] | Accuracy | ||
| 0.00 ¸ 199.9 mW (*)
200 ¸ 1999 mW (*) |
0.1 mW (*)
1 mW (*) |
±(5.0% rdg 1mW) (*) | ||
| 0.01 ¸ 9.99 W
10.0 ¸ 199.9 W |
0.01 W
0.1 W |
±(5.0% rdg 3dgt) | ||
| (*) By means of IMP57 optional accessory | ||||
| Maximum test current:
Test voltage ranges: Protection type: Insulation materials: |
5.81A (at 265V); 10.10A (at 457V)
100¸265V (Line-Neutral) / 173¸460V (Line-Line); 50/60Hz ± 5% MCB (B, C, D, K), Fuse (gG, aM) PVC, Rubber butyl, EPR, XLPE |
|||
| First fault current (IT systems) | ||||
| Range (mA) | Resolution (mA) | Accuracy | ||
| 0.1 – 0.9
1 – 999 |
0.1
1 |
±(5.0% rdg 1dgt)
±(5.0% rdg 3dgt) |
||
| Limit contact voltage (ULIM) : | 25V, 50V | |||
| RCD test (Molded case type) | ||||
| RCD type:
Rated tripping currents (IΔN): Line-PE, Line-N voltage: Frequency: |
AC, A, B – General (G), Selective (S) and Delayed (D)
10mA, 30mA, 100mA, 300mA, 500mA, 650mA, 1000mA 100V -265V RCD type AC and A, 190V -265V RCD type B 50/60Hz ± 5% |
|||
| RCD tripping current (Molded case type – RCD General) | ||||
| RCD type | IΔN | Range IΔN (mA) | Resolution (mA) | Accuracy IΔN |
| AC, A | IΔN = 10mA | (0.3 – 1.1) IΔN | ≤ 0.1 IΔN | – 0%, 10%IΔN |
| 10mA <IΔN ≤650mA | – 0%, 5%IΔN | |||
| B | 30mA ≤IΔN ≤100mA | |||
| RCD Molded type tripping time range [ms] (TT/TN system) | |||||||||||||||||||
| x 1/2 | x 1 | x 2 | x 5 | AUTO | Ramp | ||||||||||||||
| G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | ||
| 10mA | AC
A B |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
200
200 . |
250
250 . |
50
50 . |
150
150 . |
√
√ . |
√
√ . |
310
310 . |
|||||
| 30mA – 100mA | AC
A B |
999
999 999 |
999
999 999 |
999
999 999 |
999
999 999 |
999
999 999 |
999
999 999 |
200
200 . |
250
250 . |
50
50 . |
150
150 . |
√
√ . |
√
√ . |
310
310 310 |
|||||
| 300mA | AC
A B |
999
999 999 |
999
999 999 |
999
999 999 |
999
999 999 |
999
999 999 |
999
999 999 |
200
200 . |
250
250 . |
50
50 . |
150
150 . |
√
√ . |
√
√ . |
310
310 . |
|||||
| 500mA – 650mA | AC
A B |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
200
200 . |
250
250 . |
50
. . |
150
. . |
√
. . |
√
. . |
310
310 . |
|||||
| 1000mA | AC
A B |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
999
999 . |
200
. . |
250
. . |
||||||||||
| Resolution: 1ms, Accuracy: ±(2.0%rdg 2dgt) | |||||||||||||||||||
| RCD Molded type tripping time range [ms] (IT system) | |||||||||||||||||||
| x 1/2 | x 1 | x 2 | x 5 | AUTO | Ramp | ||||||||||||||
| G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | ||
| 10mA | AC
A B |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
200
. . |
250
. . |
50
. . |
150
. . |
√
. . |
√
. . |
310
. . |
|||||
| 30mA
100mA 300mA |
AC
A B |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
200
. . |
250
. . |
50
. . |
150
. . |
√
. . |
√
. . |
310
. . |
|||||
| 500mA
650mA |
AC
A B |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
200
. . |
250
. . |
50
. . |
150
. . |
√
. . |
√
. . |
310
. . |
|||||
| 1000mA | AC
A B |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
999
. . |
200
. . |
250
. . |
||||||||||
| Resolution: 1ms, Accuracy: ±(2.0%rdg 2dgt) | |||||||||||||||||||
| Test on earth leakage delay tester RCDs (with RCDX10 optional accessory) | ||||
| RCD type:
Rated tripping currents (IΔN): Line-PE, Line-N voltage: Frequency: |
AC, A, B – General (G), Selective (S) and Delayed (D)
0.3A ¸ 10A 100V -265V RCD type AC and A, 190V -265V RCD type B 50/60Hz ± 5% |
|||
| Earth leakage delay tester RCDs tripping current (RCD General) | ||||
| RCD type | IΔN | Range IΔN [mA] | Resolution [mA] | Accuracy IΔN |
| AC, A | 300mA ≤IΔN ≤6.5A | (0.3¸ 1.1) IΔN | ≤ 0.1IΔN | – 0%, 5%IΔN |
| B | 300mA ≤IΔN ≤1A | |||
| Earth leakage delay tester RCDs trip out time range [ms] (TT/TN system) | |||||||||||||||||||
| x 1/2 | x 1 | x 2 | x 5 | AUTO | Ramp | ||||||||||||||
| G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | ||
| 0.3A – 1.0A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | |||||
| A | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | ||||||
| B | 999 | 999 | 999 | 999 | 999 | 999 | 310 | ||||||||||||
| 1.1A – 3.0A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | |||||
| A | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | ||||||
| B | 999 | 999 | 999 | 999 | 999 | 999 | |||||||||||||
| 3.1A –6.5A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | |||||
| A | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | ||||||
| B | 999 | 999 | 999 | 999 | 999 | 999 | |||||||||||||
| 6.6A – 10.0A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | ||||||||||
| A | 999 | 999 | 999 | 999 | 999 | 999 | |||||||||||||
| B | |||||||||||||||||||
| Resolution: 1ms, Accuracy: ±(2.0%rdg 2dgt) | |||||||||||||||||||
| Earth leakage delay tester RCDs trip out time range [ms] (IT system) | |||||||||||||||||||
| x 1/2 | x 1 | x 2 | x 5 | AUTO | Ramp | ||||||||||||||
| G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | G | S | D | ||
| 0.3A – 1.0A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | |||||
| A | |||||||||||||||||||
| B | |||||||||||||||||||
| 1.1A – 3.0A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | |||||
| A | |||||||||||||||||||
| B | |||||||||||||||||||
| 3.1A –6.5A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | 50 | 150 | √ | √ | 310 | |||||
| A | |||||||||||||||||||
| B | |||||||||||||||||||
| 6.6A – 10.0A | AC | 999 | 999 | 999 | 999 | 999 | 999 | 200 | 250 | ||||||||||
| A | |||||||||||||||||||
| B | |||||||||||||||||||
| Resolution: 1ms, Accuracy: ±(2.0%rdg 2dgt) | |||||||||||||||||||
| RA – Non-trip earth loop impedance | ||||
| Test voltage: | 100-265V (Line-PE), 50/60Hz ± 5% | |||
| RA – Systems with Neutral wire | ||||
| Range [Ω] | Resolution [Ω] | Accuracy | ||
| 0.01 – 9.99 | 0.01 | -0%, (5.0% rdg 0.1Ω) | ||
| 10.0 -199.9 | 0.1 | -0%, (5.0% rdg 1Ω) | ||
| 200 -1999 | 1 | -0%, (5.0% rdg 3Ω) | ||
| Test current: | ~10mA | |||
| RA – Systems without Neutral wire | ||||
| Range [Ω] | Resolution [Ω] | Accuracy | ||
| 1 – 1999 | 1 | -0%, (5.0% rdg 3dgt) | ||
| Test current: < ½ IΔN set | ||||
| Contact voltage (RCD and Ra test) | ||||
| 1 – 1999 | 1 | -0%, (5.0% rdg 3dgt) | ||
| Contact voltage (EARTH test – TT system) | ||||
| Range [V] | Resolution [V] | Accuracy | ||
| 0 – 99.9 | 0.1 | -0%, (5.0% rdg 3V) | ||
| Contact voltage (EARTH test – TN system) | ||||
| Range [V] | Resolution [V] | Accuracy | ||
| 0 – 99.9 | 0.1 | -0%, (5.0% rdg 3V) | ||
| 100 – 999 | 1 | |||
| Ground resistance with 3-wire method | ||||
| Range [Ω] | Resolution [Ω] | Accuracy | ||
| 0.01 – 9.99 | 0.01 | ±(5.0% rdg 3dgt) | ||
| 10.0 – 99.9 | 0.1 | |||
| 100 – 999 | 1 | |||
| 1.00k – 49.99k | 0.01k | |||
| Test current: <10mA – 77.5Hz, Open-circuit voltage: < 20Vrms
(*) Add 5% to the accuracy if the probe resistances (Rs or Rh) > 100 x Rmeas |
||||
| Soil resistivity with 4-wire Wenner method | ||||
| Range [Ωm] | Resolution [Ωm] | Accuracy (*) | ||
| 0.06 – 9.99 | 0.01 | ±(5.0% rdg 3dgt) | ||
| 10.0 – 99.9 | 0.1 | |||
| 100 – 999 | 1 | |||
| 1.00k – 9.99k | 0.01k | |||
| 10.0k – 99.9k | 0.1k | |||
| 100k – 999k (*) | 1k | |||
| 1.00M – 3.14M (*) | 0.01M | |||
| (*) with distance d=10m, Distance “d” range: 1 -10m | ||||
| Test current: <10mA – 77.5Hz, Open-circuit voltage: < 20Vrms | ||||
| Phase sequence rotation with 1-wire method | ||||
| Voltage range P-N, P-PE[V] | Frequency range | |||
| 100 – 265 | 50Hz/60Hz ± 5% | |||
| Measurement is only carried out by direct contact with metal live parts (not on insulation sheath) | ||||
| Voltage drop on main power lines (ΔV%) | ||||
| Range (%) | Resolution (%) | Accuracy | ||
| 0 – 100 | 0.1 | ±(10.0% rdg 4dgt) | ||
| Voltage range Phase-PE, Phase-Neutral: 100 -265V, Frequency: 50/60Hz ± 5% | ||||
| Leakage current (by HT96U optional clamp transducer) | ||||
| FS clamp AC (A) | Resolution | Accuracy | ||
| 1 | 0.1mA | ±(1.0% rdg 20dgt) | ||
| 10 ≤ FS <300 | 0.1A | |||
| 1 < FS <10 | 0.01A | |||
| 300 ≤ FS <3000 | 1A | |||
| Environmental parameters (AUX function) | ||||
| Parameter | Range | Resolution | Accuracy | |
| Temperature [°C] | -20°C – 80°C | 0.1 °C | ±(2.0%rdg 2dgt) | |
| Temperature [°F] | -4°F – 176°F | 0.1 °F | ||
| Relative humidity [%HR] | 0 – 100%HR | 0.1% UR | ||
| DC output voltage | 0.1mV – 1.0V | 0.1mV | ||
| Illuminance [Lux] | 0.001Lux – 20.00 Lux (*) | 0.001 – 0.02 Lux | ||
| 0.1 Lux – 2000 Lux (*) | 0.1 – 2 Lux | |||
| 1 Lux – 20 kLux (*) | 1 – 20 Lux | |||
| (*) Accuracy of HT53 lux probe is according to Class AA | ||||
| ELECTRICAL SPECIFICATIONS – PQA SECTION | ||||
| AC TRMS Voltage (Phase-Neutral) | ||||
| Range [V] | Resolution [V] | Accuracy | ||
| 15.0—380.0 | 0.1V | ±(1.0% rdg 1dgt) | ||
| Allowed crest factor: ≤ 1,5 ; Frequency: 42 ¸ 69.0 Hz | ||||
| AC TRMS Voltage (Phase-Phase) | ||||
| Range [V] | Resolution [V] | Accuracy | ||
| 15.0 – 660.0 | 0.1V | ±(1.0% rdg 1dgt) | ||
| Allowed crest factor: ≤ 1,5 ; Frequency: 42 ¸ 69.0 Hz | ||||
| Frequency | ||||
| Range [Hz] | Resolution [Hz] | Accuracy | ||
| DC, 42 – 69.0 | 0.01 | ±(2.0% rdg 2dgt) | ||
| Allowed voltage: 15.0¸ 660V; Allowed current: 5%FS clamp ¸ FS clamp | ||||
| DC/ AC TRMS Current (STD clamp) | ||||
| FS clamp | Range [A] | Resolution [A] | Accuracy | |
| ≤ 10A | 5% FS – 9.99 | 0.01 | ±(1.0% rdg 3 dgt) | |
| 10A ≤ FS ≤ 300 | 5% FS – 299.9 | 0.1 | ||
| 300A ≤ FS ≤ 3000 | 5% FS – 2999 | 1 | ||
| Range: 5 – 999.9 mV; Values under 5mV are zeroed
Allowed crest factor: ≤ 3; Frequency: 42 – 69.0 Hz |
||||
| AC TRMS Current (FLEX clamp – 300A AC) | ||||
| Range [mV] | Frequency [Hz] | Resolution | Accuracy | Overload protection |
| 0.085 – 85.0 | 42 – 69.0 | 8.5µV | ±(0.5% rdg 0.17% FS) | 10V |
| Allowed crest factor ≤ 3, Values under 1A are zeroed | ||||
| AC TRMS Current (FLEX clamp – 3000A AC) | ||||
| Range [mV] | Frequency [Hz] | Resolution | Accuracy | Overload protection |
| 0.425 – 255.0 | 42 – 69.0 | 85µV | ±(0.5% rdg 0.17% FS) | 10V |
| Allowed crest factor ≤ 3, Values under 5A are zeroed | ||||
| DC Power | ||||
| FS clamp | Range [kW] | Resolution [kW] | Accuracy | |
| ≤ 10A | 0.000 – 9.999 | 0.001 | ≤(2.0% rdg 7dgt) | |
| 10.00 – 99.99 | 0.01 | |||
| 10A ≤ FS ≤ 200 | 0.00 – 99.99 | 0.01 | ||
| 100.0 – 999.9 | 0.1 | |||
| 200A ≤ FS ≤ 1000 | 0.0 – 999.9 | 0.1 | ||
| 1000 – 9999 | 1 | |||
| 1000A ≤ FS ≤3000 | 0 – 9999 | 1 | ||
| Active power (@ 230V, I > 5%FS, cosφ ≥ 0.5, f=50.0Hz) | ||||
| FS clamp | Range [kW] | Resolution [kW] | Accuracy | |
| ≤ 10A | 0.000 – 9.999 | 0.001 | ≤(2.0% rdg 7dgt) | |
| 10.00 – 99.99 | 0.01 | |||
| 10A ≤ FS ≤ 200 | 0.00 – 99.99 | 0.01 | ||
| 100.0 – 999.9 | 0.1 | |||
| 200A ≤ FS ≤ 1000 | 0.0 – 999.9 | 0.1 | ||
| 1000 – 9999 | 1 | |||
| 1000A ≤ FS ≤3000 | 0 – 9999 | 1 | ||
| Reactive power (@ 230V, I > 5%FS, cosφ < 0.9, f=50.0Hz) | ||||
| FS clamp | Range [kVAr] | Resolution [kVAr] | Accuracy | |
| ≤ 10A | 0.000 – 9.999 | 0.001 | ≤(2.0% rdg 7dgt) | |
| 10.00 – 99.99 | 0.01 | |||
| 10A ≤ FS ≤ 200 | 0.00 – 99.99 | 0.01 | ||
| 100.0 – 999.9 | 0.1 | |||
| 200A ≤ FS ≤ 1000 | 0.0 – 999.9 | 0.1 | ||
| 1000 – 9999 | 1 | |||
| 1000A ≤ FS ≤3000 | 0 – 9999 | 1 | ||
| Power factor / cosφ (@ 230V, I > 5% FS) | ||||
| Range | Resolution | Accuracy | ||
| 0.70c -1.00—0.70i | 0.01 | ±(2.0% rdg 3dgt) | ||
| Voltage harmonics (@ 230V in 1Ph systems, 400V in 3Ph systems) | ||||
| Range [%] | Resolution [%] | Order | Accuracy | |
| 0.1 – 100.0 | 0.1 | DC, 01 = 49 | ±(5.0% rdg 5dgt) | |
| Frequency of fundamental: 42 – 69.0 Hz
Harmonics are zeroed at the below conditions: · DC : DC value <0.5% fundamental value or DC value < 1.0V · 1° Harmonic: value of 1° Harmonic < 15V · 2nd – 49th Harmonics: harmonic value <0.5% fundamental value or if value < 1.0V |
||||
| Current harmonics | ||||
| Range [%] | Resolution [%] | Order | Accuracy | |
| 0.1 – 100.0 | 0.1 | DC, 01 = 49 | ±(5.0% rdg 5dgt) | |
| Frequency of fundamental: 42 – 69.0 Hz
Harmonics are zeroed at the below conditions: · DC : DC value <0.5% fundamental value or DC value < 0.5%FS clamp · 1° Harmonic: value of 1° Harmonic < 0.5%FS clamp · 2nd – 49th Harmonics: harmonic value <0.5% fundamental value or if value < 0.5%FS clamp |
||||
| Voltage anomalies (Phase-Neutral, Phase-PE) | ||||
| Range [V] | Resolution [V] | Resolution [ms] | Accuracy [V] | Accuracy [ms] |
| 15.0 – 380 | 0.2 | 20ms | ±(1.0% rdg 2dgt) | ± 1cycle |
| Voltage anomalies (Phase- Phase) | ||||
| 15.0 – 660 | 0.2 | 20ms | ±(1.0% rdg 2dgt) | ± 1cycle |
| GENERAL SPECIFICATIONS | |
| DISPLAY AND MEMORY: | |
| Features:
Memory safety section: Memory PQA section: Communication: |
TFT, touch screen, colour graphic LCD, 320 x 240mm
999 locations, 3 marker levels 8MB (not expanded) Optical-USB and built-in WiFi |
| POWER SUPPLY: | |
| Batteries:
Battery life: . Recharging time: External charger: Auto Power OFF: |
6 x 1.2V(rechargeable) type AA or 6 x 1.5V type AA
> 500 test for each safety functions > 6 hours in recording approx. 12 hours 100-240VAC, 50/60Hz / 15VDC, CAT IV 300V after 5 min of idleness (disabled) |
| MECHANICAL FEATURES: | |
| Dimensions (L x W x H):
Weight (included batteries): |
225 x 165 x 75mm
1.2kg |
| WORKING ENVIRONMENTAL CONDITIONS: | |
| Reference temperature:
Working temperature: Allowed relative humidity: Storage temperature: Storage humidity: |
23°C ± 5°C
0° – 40°C <80%HR -10 – 60°C <80%HR |
| GENERAL REFERENCE STANDARDS: | |
| Safety of measuring instruments:
Product type standard: EMC : Technical documentation : Insulation: Pollution degree: Encapsulation : Measurement category: Max height of use: |
IEC/EN61010-1, IEC/EN61010-031, IEC/EN61010-2-032
IEC/EN61557-1-2-3-4-5-6-7-10 IEC/EN61326-1 IEC/EN61187 double insulation 2 IP40 CAT IV 300V to ground, CAT III 350V to ground max 600V among inputs 2000m |
| TEST VERIFIES REFERENCE STANDARDS: | |
| Continuity test with 200mA:
Insulation resistance: Earth resistance: Fault loop impedance: RCD test: Phase sequence: Multifunction: Prospective short circuit current: Earth resistance on TN systems: Power quality: |
IEC/EN61557-4
IEC/EN61557-2 IEC/EN61557-5 IEC/EN61557-3 IEC/EN61557-6 (only Phase-Neutral-Ground systems) IEC/EN61557-7 IEC/EN61557-10 EN60909-0 EN61936-1 EN50522 EN50160 |
| This instrument complies with the requirements of the European Low Voltage Directives 2014/35/EU (LVD) and EMC 2014/30/EU
This instrument complies with the requirements of the European 2011/65/EU (RoHS) and with the requirements of the European 2012/19/EU (WEEE) |
|