Fluke 116

  • DC millivolts
    • Range/resolution 600.0 mV / 0.1 mV
    • Accuracy ±0.5% 2
  • DC volts
    • Range/resolution
      • 6.000 V / 0.001 V
        60.00 V / 0.01 V
        600.00 V / 0.1 V
    • Accuracy ±0.5% 2
  • Auto volts
    • Range/resolution 600.0 V / 0.1 V
    • Accuracy
      • 2.0% 3 (DC, 45 Hz to 500 Hz)
        4.0% 3 (500 Hz to 1 kHz)
  • AC millivolts¹ True RMS
    • Range/resolution 600.0 mV / 0.1 mV
    • Accuracy
      • 1.0% 3 (DC, 45 Hz to 500 Hz)
        2.0% 3 (500 Hz to 1 kHz)
  • AC volts¹ True RMS
    • Range/resolution
      • 6.000 V / 0.001 V
        60.00 V / 0.01 V
        600.0 V / 0.1 V
    • Accuracy
      • 1.0% 3 (DC, 45 Hz to 500 Hz)
        2.0% 3 (500 Hz to 1 kHz)
  • Continuity
    • Range/resolution 600 Ω / 1 Ω
    • Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
      500 μs or longer.
  • Ohms
    • Range/resolution
      • 600.0 Ω / 0.1 Ω
        6.000 kΩ / 0.001 kΩ
        60.00 kΩ / 0.01 kΩ
        600.0 kΩ / 0.1 kΩ
        6.000 MΩ / 0.001 MΩ
    • Accuracy 0.9% 1
    • Range/resolution 40.00 MΩ / 0.01 MΩ
    • Accuracy 5% 2
  • Diode test
    • Range/resolution 2.00 V / 0.001 V
    • Accuracy 0.9% 2
  • Capacitance
    • Range/resolution
      • 1000 nF / 1 nF
        10.00 μF / 0.01 μF
        100.0 μF / 0.1 μF
        9999 μF / 1 μF
        100 μF to 1000 μF
      • Accuracy 1.9% 2
    • Range/resolution > 1000 μF
      • Accuracy 5% 20%
  • Lo-Z capacitance
    • Range 1 nF to 500 μF
    • Accuracy 10% 2 typical
  • Temperature² (Type-K thermocouple)
    • Range/resolution -40°C to 400°C / 0.1°C
    • Accuracy 1% 10²
    • Range/resolution -40°F to 752°F / 0.2°F
    • Accuracy 1% 18²
  • AC μA true-RMS (45 Hz to 500 Hz)
    • Range/resolution 600.0 μA / 0.1 μA
    • Accuracy 1.5% 3
  • DC μamps
    • Range/resolution 600.0 μA / 0.1 μA
  • Hz (V or A input)²
    • Range/resolution
      • 99.99 Hz / 0.01 Hz
        999.99 Hz / 0.1 Hz
        9.999 Hz / 0.001 Hz
        50.00 Hz / 0.01 Hz
    • Accuracy 0.1% 2
  1. All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
  2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
  3. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
  4. Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
  •  Maximum voltage between any terminal and earth ground 600 V
  • Environmental
    • Operating Temperature  -10°C to 50°C
    • Storage Temperature  -40°C to 60°C
  • Safety
    • Surge protection
      • 6 kV peak per IEC 61010–1 600 V CAT III,
      • Pollution Degree 2
  • Display
    • Digital: 6,000 counts, updates 4 per second
  • Bar graph
    • 33 segments, updates 32 per second
  • Features
    • VoltAlert™ technology for non-contact voltage detection
    • AutoVolt automatic AC/DC voltage selection
    • Low input impedance: helps prevent false readings due to ghost voltage
    • Large white LED backlight to work in poorly lit areas
    • True RMS for accurate measurements on non-linear loads
    • Measures 10 A (20 A overload for 30-seconds)
    • Resistance, continuity, frequency and capacitance
    • Min/Max/Average with elapsed time to record signal fluctuations
    • Compact ergonomic design for one-handed operation
    • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
    • CAT III 600 V safety rated
  • Mechanical & General
    • Size  167 x 84 x 46 mm
    • Weight  550 g
    • Warranty 3 years
    • Battery Life  9 volt Alkaline:~400 hours typical, without backlight
  • Included accessories:
    • 4 mm silicone test lead set
    • 80BK Integrated Temperature probe
    • Holster
    • Installed 9 V battery
    • User manual
  • Optional Accessories
    • Cases, bags and holsters
    • Meter hanger kits
    • Probes
      • HV
      • Current clamp
      • Fibre Optic
      • Pressure
      • Temperature
    • Test Leads
    • Clips
    • Probe lights

Fluke 62 MAX Infrared Thermometer

  • Temperature
    • Range -30 °C to 650 °C (-22 °F to 1202 °F)
    • Accuracy
      • ±1.0 °C or ±1.0% of reading, whichever is greater
        -10 °C to 0 °C: ±2.0
        -30 °C to -10 °C: ±3.0
  • Response Time (95%)
    • Fluke 62 MAX <300 ms (95% of reading)
    • Spectral Response 8 to 14 microns
    • Emissivity 0.10 to 1.00
  • Resolution
    • Optical 12:1 (calculated at 90% energy)
    • Display 0.1 °C (0.2 °F)
  • Repeatability of Readings
    • ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
  • AC current
    • Range 400.0 A
    • Accuracy
      • 2 % ± 5 digits (45 Hz to 65 Hz)
        2.5 % ± 5 digits (65 Hz to 400 Hz)
  • Mechanical & General
    • Size  175 x 85 x 75 mm
    • Weight  255 g
    • Warranty 2 year
    • Battery life Alkaline AA ~ 8 hours with laser and backlight on
  • Environmental
    • Operating Temperature  0 °C to 50 °C
    • Storage Temperature  -20 °C to 60 °C
    • Operating Humidity 10 % to 90 % RH non-condensing at 30 °C
    • Operating Altitude 2000 meters above mean sea level
    • Storage Altitude 12,000 meters above mean sea level
    • IP Rating IP 54 per IEC 60529
    • Drop Test 3 meters
    • Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
    • EMC EN 61326-1:2006 EN 61326-2:2006
  • Safety
    • Standards and Agency Approval
      • Compliance EN/IEC 61010-1: 2001
      • Laser Safety FDA and EN 60825-1 Class II
  • Features
    • Key Benefits
      • Dust and water-resistant: IP54 rated for dust and water resistance.
      • Rugged: 3-meter (9.8-foot) drop tested.
      • Completely redesigned for a more natural hand fit.
      • Small,lightweight and clips to your tool belt or belt loop and easily fits into your tool box.
    • Additional Features
      • Distance to spot: Precise laser technology makes for more accurate and repeatable measurements.
      • Dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots.
      • Large screen with backlight makes data easier to read, even in dark areas.
      • Displays the minimum, maximum or average temperature, or the difference between two measurements.
      • Hi and Lo alarms for rapid display of measurements outside the limits.
      • Powered by a single, standard AA battery.

 